How much do you know to promote hospital door manufacturer?It is an automatic door installed in clean rooms, clean corridors, operating rooms and other similar cleanliness requirements.I'm sure everyone will see different materials and different openings.The medical door manufacturer will share with you today the installation standards for medical personnel.
1, the door cover installation standard hospital door manufacturers lead everyone to understand the installation standard of the medical door
In the standard for the installation of indoor wooden doors, the hospital door manufacturer understands that the door cover has the requirement that the assembly connection be tight, flat and without black seams;Fixed parts should be tight;Pay attention to the diagonal of the door cover.Alignment shall be within 1 mm (2 m) and 1.5 mm (greater than 2 m).Installation of the door cover should be horizontal and vertical, vertical degree 2 mm, horizontal flatness 1 mm.
2. Cable installation standard
Wood ward door/department door wiring group shall be fixed with glue together with door cover and wall, and the interface shall be smooth, tight and seamless.The medical door manufacturer recommends that you see if it has a side line and a side line after installation.In terms of error, the bending of the sleeve is allowed to have a deviation of 1 mm.
3. Door fan installation standard
Door leaf level off, perpendicular, switch is agile, it is the basic installation standard of indoor wooden door.Additional, door door and door cover should reveal, the lower clearance between door cover and door door should be 6 to 7 millimeter, door door should be combined closely with sealing strip, oscillate phenomenon impossible to happen.
4. Installation standard of hardware accessories
High quality automatic door belt hardware accessories in the hinge should be vertical and level, the size of the notch should be consistent with the hinge;The door lock should be accurate, standardized and the size should be the same as the size of the lock body and the lock plate.Connector and lock lamp should be flexible and smooth.Smooth.The medical door manufacturer reminds everyone not to forget the hardware during the inspection.
Medical door manufacturer
Believe everybody passes the detailed introduction of manufacturer of medical door, have certain understanding to the installation standard of medical personnel, hope to have help to everybody.In addition, xiaobian suggest that you should pay special attention to the quality of medical door installation!