How to use different color steel medical door?

Your current location: Home >> News >> Industry news

How to use different color steel medical door?

Date of release:2019-04-30 Author: Click:

不同颜色的钢质医用门该如何使用?

How to use different color steel medical door?As the device of the entrance and exit of each department of the hospital, the steel medical door can play the role of space separation.Different styles of hospital decoration can be used to design and manufacture different colors of steel medical doors.

Medical children steel door, the hospital door manufacturer for children, they are too lazy to think about complex color names, mainly is sensitive to a single color, so in the interior design of children's hospital, simple color can improve children's interest, so in general, the warm color attune is used to match the ward door: yellow, red, etc

The main target of the central hospital is adults, giving a sense of maturity and stability.Therefore, the medical doors of the central hospital tend to be in cool colors, such as blue and green.

The steel medical door of maternal and child health hospital has the same function as children's hospital.The main target group is women and children to create a fashionable, warm and soft female medical environment.Therefore, pale purple and pink series are usually used.

The steel medical door design of hospital of traditional Chinese medicine must mainly maintain the need of utilizing the characteristics of traditional Chinese medicine.Therefore, the general use of wood grain transfer brown red series, both reflects the Chinese tradition, and give a person a sense of stability, credibility, practical.

Geriatric hospital hospital ward door is mainly used by the elderly.Due to the aging of sensory organs such as vision and touch, the elderly may experience spatial blurring, which weakens the ability to fine perceive things and hinders the intake of external information.On the basis of deep understanding of the physiological and psychological needs of the elderly, the theme color should be high brightness, medium purity of color, such as beige, light pink, light blue, to create a bright and relaxed atmosphere.Space atmosphere.

Medical open automatic doors can not only be designed according to different types of hospitals, but also according to different department design style design.How to use different color steel medical door?

When the automatic medical door is running, the door opening or closing action is too slow, mainly because the control device opening or closing speed knob is too low;Too much running resistance;The belt is slack and there is not enough tension.The control can then be adjusted to open or close the door speed knob;Turn off the power, move the door fan by hand, check whether there are obstacles in the moving parts;Adjust belt tension.

In medical work, when the medical automatic door runs, the door opens automatically, interference exists in the sensor detection area, another sensor detection area overlaps, and the door is in the detection area.Therefore, interference objects in the sensor detection area can be removed, the sensor interference prevention switch can be switched, and the sensor detection area and sensitivity can be adjusted.

If there is no collision in the operation of the medical automatic door, it may be because the control device or motor has a fault, can replace the control device or motor.When the medical automatic door running, the door does not move.The main reasons are power failure, poor electrical connection, locking or double door interlock.Then check the power supply, connector, keep it in good contact, unlock or wait for another door to close.

The operation of the medical door is not closed, generally because there is interference in the sensor detection area;The light receiver on the safety photoelectric sensor is attached with debris and the optical axis is deflected.Control device failure;The recoil setting is too low, therefore, to eliminate interference in the sensor detection area, replace the sensor, clean the receiver, adjust the optical axis, turn off the power and start up several times instead of closing the door to replace the control device and increase recoil.

不同颜色的钢质医用门该如何使用?


The address of this article:http://en.dorcoo.com/news/389.html

Key word:

All rights reserved © Ningbo Dorcoo Automatic Door Co., Ltd. All rights reserved 
  Huaqi
  • Service
  • number
    13605882116
  • Message
  • web site
  • Online Service
    Please leave a message for us
    Please input the message here, and we will contact you as soon as possible.
    name
    Contacts
    Telephone
    Telephone
    mailbox
    mailbox
    address
    address